{"id":5732,"date":"2023-10-06T20:06:17","date_gmt":"2023-10-06T14:36:17","guid":{"rendered":"https:\/\/pharmaceuticalcarrier.com\/?p=5732"},"modified":"2023-10-06T20:06:27","modified_gmt":"2023-10-06T14:36:27","slug":"standard-operating-procedure-sop-for-sampling-of-raw-material","status":"publish","type":"post","link":"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/06\/standard-operating-procedure-sop-for-sampling-of-raw-material\/","title":{"rendered":"Standard Operating Procedure (SOP) for Sampling of Raw Material"},"content":{"rendered":"\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_76 counter-hierarchy ez-toc-counter ez-toc-transparent ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewBox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewBox=\"0 0 24 24\" version=\"1.2\" baseProfile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/06\/standard-operating-procedure-sop-for-sampling-of-raw-material\/#1_Purpose_of_Sampling_of_Raw_Material\" >1. Purpose of Sampling of Raw Material<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/06\/standard-operating-procedure-sop-for-sampling-of-raw-material\/#2_Scope_of_Sampling_of_Raw_Material\" >2. Scope of Sampling of Raw Material<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/06\/standard-operating-procedure-sop-for-sampling-of-raw-material\/#3_Definitions_involved_in_Sampling_of_Raw_Material\" >3. Definitions involved in Sampling of Raw Material<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/06\/standard-operating-procedure-sop-for-sampling-of-raw-material\/#31_Raw_Material\" >3.1 Raw Material:<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/06\/standard-operating-procedure-sop-for-sampling-of-raw-material\/#32_Sampling\" >3.2 Sampling:<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/06\/standard-operating-procedure-sop-for-sampling-of-raw-material\/#33_Representative_Sample\" >3.3 Representative Sample:<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/06\/standard-operating-procedure-sop-for-sampling-of-raw-material\/#4_Responsibilities\" >4. Responsibilities<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/06\/standard-operating-procedure-sop-for-sampling-of-raw-material\/#41_Quality_Control_Manager\" >4.1. Quality Control Manager<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/06\/standard-operating-procedure-sop-for-sampling-of-raw-material\/#42_Procurement_Officer\" >4.2. Procurement Officer<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/06\/standard-operating-procedure-sop-for-sampling-of-raw-material\/#43_Laboratory_Analysts\" >4.3. Laboratory Analysts<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/06\/standard-operating-procedure-sop-for-sampling-of-raw-material\/#5_Raw_Material_Sampling_Procedures\" >5. Raw Material Sampling Procedures<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/06\/standard-operating-procedure-sop-for-sampling-of-raw-material\/#51_Pre-Sampling_Preparation\" >5.1. Pre-Sampling Preparation<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-13\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/06\/standard-operating-procedure-sop-for-sampling-of-raw-material\/#52_Selection_of_Sampling_Locations\" >5.2. Selection of Sampling Locations<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-14\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/06\/standard-operating-procedure-sop-for-sampling-of-raw-material\/#53_Sampling_Techniques\" >5.3. Sampling Techniques<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-15\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/06\/standard-operating-procedure-sop-for-sampling-of-raw-material\/#54_Sample_Size_and_Quantity\" >5.4. Sample Size and Quantity<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-16\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/06\/standard-operating-procedure-sop-for-sampling-of-raw-material\/#55_Documentation\" >5.5. Documentation<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-17\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/06\/standard-operating-procedure-sop-for-sampling-of-raw-material\/#56_Sample_Handling_and_Storage\" >5.6. Sample Handling and Storage<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-18\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/06\/standard-operating-procedure-sop-for-sampling-of-raw-material\/#6_Deviations_and_Reporting\" >6. Deviations and Reporting<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-19\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/06\/standard-operating-procedure-sop-for-sampling-of-raw-material\/#61_Deviations\" >6.1. Deviations<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-20\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/06\/standard-operating-procedure-sop-for-sampling-of-raw-material\/#62_Reporting\" >6.2. Reporting<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-21\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/06\/standard-operating-procedure-sop-for-sampling-of-raw-material\/#7_Records_and_Retention\" >7. Records and Retention<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-22\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/06\/standard-operating-procedure-sop-for-sampling-of-raw-material\/#71_Records\" >7.1. Records<\/a><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"1_Purpose_of_Sampling_of_Raw_Material\"><\/span><strong>1. Purpose of Sampling of Raw Material<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>The purpose of this Standard Operating Procedure (SOP) is to establish guidelines and procedures for the proper sampling of raw materials used in [Company Name]&#8217;s production processes. This SOP ensures that representative samples are obtained for quality control and testing purposes, maintaining product quality and compliance with regulatory requirements.<\/p><div class=\"pharm-content\" id=\"pharm-3982791260\"><script async src=\"\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-8402705006112223\" crossorigin=\"anonymous\"><\/script><ins class=\"adsbygoogle\" style=\"display:block;\" data-ad-client=\"ca-pub-8402705006112223\" \ndata-ad-slot=\"7652789694\" \ndata-ad-format=\"auto\"><\/ins>\n<script> \n(adsbygoogle = window.adsbygoogle || []).push({}); \n<\/script>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"2_Scope_of_Sampling_of_Raw_Material\"><\/span><strong>2. Scope of Sampling of Raw Material<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>This SOP applies to all personnel involved in the procurement, testing, and quality control of raw materials within [Company Name]. It covers procedures for sampling various types of raw materials, including but not limited to chemicals, ingredients, and components.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"3_Definitions_involved_in_Sampling_of_Raw_Material\"><\/span><strong>3. Definitions involved in Sampling of Raw Material<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"31_Raw_Material\"><\/span>3.1 <strong>Raw Material<\/strong>: <span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Any substance or component used in the manufacturing of products before any processing or conversion.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"32_Sampling\"><\/span>3.2 <strong>Sampling<\/strong>: <span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>The process of selecting and collecting a portion of a raw material that accurately represents the whole batch.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"33_Representative_Sample\"><\/span>3.3 <strong>Representative Sample<\/strong>: <span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>A sample that accurately reflects the characteristics and quality of the entire batch of raw material.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"4_Responsibilities\"><\/span><strong>4. Responsibilities<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"41_Quality_Control_Manager\"><\/span><strong>4.1. Quality Control Manager<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>4.1.1 Oversee the implementation of the raw material sampling procedures.<\/p>\n\n\n\n<p>4.1.2 Ensure that sampling activities comply with regulatory requirements and company standards.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"42_Procurement_Officer\"><\/span><strong>4.2. Procurement Officer<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>4.2.1 Coordinate with suppliers to ensure that sampling can be performed effectively.<\/p>\n\n\n\n<p>4.2.2 Provide information on the source and characteristics of raw materials to support proper sampling.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"43_Laboratory_Analysts\"><\/span><strong>4.3. Laboratory Analysts<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>4.3.1 Perform the actual sampling of raw materials as per this SOP.<\/p>\n\n\n\n<p>4.3.2 Maintain accurate records of sampling activities and submit samples for testing.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"5_Raw_Material_Sampling_Procedures\"><\/span><strong>5. Raw Material Sampling Procedures<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"51_Pre-Sampling_Preparation\"><\/span><strong>5.1. Pre-Sampling Preparation<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>5.1.1 Review the specifications and requirements for the raw material being sampled.<\/p>\n\n\n\n<p>5.1.2 Ensure that all necessary sampling equipment is clean, calibrated, and ready for use.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"52_Selection_of_Sampling_Locations\"><\/span><strong>5.2. Selection of Sampling Locations<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>5.2.1 Identify sampling locations that provide a representative sample of the raw material.<\/p>\n\n\n\n<p>5.2.2 Consider factors such as batch size, homogeneity, and regulatory requirements.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"53_Sampling_Techniques\"><\/span><strong>5.3. Sampling Techniques<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>5.3.1 Use appropriate sampling tools and methods to obtain samples.<\/p>\n\n\n\n<p>5.3.2 Take care to avoid contamination during sampling.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"54_Sample_Size_and_Quantity\"><\/span><strong>5.4. Sample Size and Quantity<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>5.4.1 Determine the required sample size based on regulatory guidelines and testing requirements.<\/p>\n\n\n\n<p>5.4.2 Collect a sufficient quantity of samples to ensure accurate analysis.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"55_Documentation\"><\/span><strong>5.5. Documentation<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>5.5.1 Record all relevant details of the sampling process, including date, time, location, personnel involved, and any deviations.<\/p>\n\n\n\n<p>5.5.2 Label each sample container with a unique identifier.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"56_Sample_Handling_and_Storage\"><\/span><strong>5.6. Sample Handling and Storage<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>5.6.1 Handle samples with care to prevent damage or contamination.<\/p>\n\n\n\n<p>5.6.2 Store samples in appropriate containers and conditions to maintain sample integrity.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"6_Deviations_and_Reporting\"><\/span><strong>6. Deviations and Reporting<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"61_Deviations\"><\/span><strong>6.1. Deviations<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>6.1.1 Document and investigate any deviations from the established sampling procedures.<\/p>\n\n\n\n<p>6.1.2 Assess the impact of deviations on product quality and report findings to the Quality Control Manager.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"62_Reporting\"><\/span><strong>6.2. Reporting<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>6.2.1 Prepare a sampling report, including all documentation and findings.<\/p>\n\n\n\n<p>6.2.2 Submit the report to the Quality Control Manager for review and approval.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"7_Records_and_Retention\"><\/span><strong>7. Records and Retention<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"71_Records\"><\/span><strong>7.1. Records<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>7.1.1 Maintain accurate records of all sampling activities, reports, and deviations.<\/p>\n\n\n\n<p>7.1.2 Retain records for the specified retention period in compliance with regulatory requirements.<\/p>\n\n\n\n<p>For more articles,&nbsp;<strong><a href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/ayurveda\/\">Kindly Click<\/a>&nbsp;here<\/strong>.<\/p>\n\n\n\n<p>For pharmaceutical jobs, follow us on<strong>&nbsp;<a href=\"https:\/\/www.linkedin.com\/company\/pharmaceuticalcarrier\/?viewAsMember=true\" target=\"_blank\" rel=\"noreferrer noopener\">LinkedIn<\/a><\/strong><\/p>\n\n\n\n<p><strong>For Editable SOPs in word format contact us on&nbsp;<a href=\"mailto:info@pharmaceuticalcarrier.com\">info@pharmaceuticalcarrier.com<\/a><\/strong><\/p>\n\n\n\n<p>For more information kindly follow us on pharmaguidelines.co.uk<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Discover a comprehensive Standard Operating Procedure (SOP) for the sampling of raw materials in a manufacturing or quality control setting. This SOP outlines procedures for selecting representative samples, handling deviations, and maintaining accurate records, ensuring product quality and compliance with regulatory standards.<\/p>\n","protected":false},"author":1,"featured_media":5599,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","footnotes":""},"categories":[165],"tags":[406,677,256,257,835,829,348,736,836,166],"class_list":["post-5732","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-standard-operating-procedure","tag-deviation-reporting","tag-laboratory-procedures","tag-quality-assurance","tag-quality-control","tag-raw-material-sampling","tag-record-keeping-2","tag-regulatory-compliance","tag-sample-handling","tag-sampling-techniques","tag-sop"],"uagb_featured_image_src":{"full":["https:\/\/pharmaceuticalcarrier.com\/wp-content\/uploads\/2023\/09\/Standard-operating-procedure.jpg",1200,720,false],"thumbnail":["https:\/\/pharmaceuticalcarrier.com\/wp-content\/uploads\/2023\/09\/Standard-operating-procedure-150x150.jpg",150,150,true],"medium":["https:\/\/pharmaceuticalcarrier.com\/wp-content\/uploads\/2023\/09\/Standard-operating-procedure-300x180.jpg",300,180,true],"medium_large":["https:\/\/pharmaceuticalcarrier.com\/wp-content\/uploads\/2023\/09\/Standard-operating-procedure-768x461.jpg",640,384,true],"large":["https:\/\/pharmaceuticalcarrier.com\/wp-content\/uploads\/2023\/09\/Standard-operating-procedure-1024x614.jpg",640,384,true],"1536x1536":["https:\/\/pharmaceuticalcarrier.com\/wp-content\/uploads\/2023\/09\/Standard-operating-procedure.jpg",1200,720,false],"2048x2048":["https:\/\/pharmaceuticalcarrier.com\/wp-content\/uploads\/2023\/09\/Standard-operating-procedure.jpg",1200,720,false],"authorship-box-avatar":["https:\/\/pharmaceuticalcarrier.com\/wp-content\/uploads\/2023\/09\/Standard-operating-procedure-150x150.jpg",150,150,true],"authorship-box-related":["https:\/\/pharmaceuticalcarrier.com\/wp-content\/uploads\/2023\/09\/Standard-operating-procedure-70x70.jpg",70,70,true],"sow-carousel-default":["https:\/\/pharmaceuticalcarrier.com\/wp-content\/uploads\/2023\/09\/Standard-operating-procedure.jpg",272,163,false]},"uagb_author_info":{"display_name":"Pharmacareer","author_link":"https:\/\/pharmaceuticalcarrier.com\/index.php\/author\/grandirpharmagmail-com\/"},"uagb_comment_info":0,"uagb_excerpt":"Discover a comprehensive Standard Operating Procedure (SOP) for the sampling of raw materials in a manufacturing or quality control setting. This SOP outlines procedures for selecting representative samples, handling deviations, and maintaining accurate records, ensuring product quality and compliance with regulatory standards.","amp_enabled":true,"_links":{"self":[{"href":"https:\/\/pharmaceuticalcarrier.com\/index.php\/wp-json\/wp\/v2\/posts\/5732","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pharmaceuticalcarrier.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/pharmaceuticalcarrier.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/pharmaceuticalcarrier.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/pharmaceuticalcarrier.com\/index.php\/wp-json\/wp\/v2\/comments?post=5732"}],"version-history":[{"count":1,"href":"https:\/\/pharmaceuticalcarrier.com\/index.php\/wp-json\/wp\/v2\/posts\/5732\/revisions"}],"predecessor-version":[{"id":5733,"href":"https:\/\/pharmaceuticalcarrier.com\/index.php\/wp-json\/wp\/v2\/posts\/5732\/revisions\/5733"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pharmaceuticalcarrier.com\/index.php\/wp-json\/wp\/v2\/media\/5599"}],"wp:attachment":[{"href":"https:\/\/pharmaceuticalcarrier.com\/index.php\/wp-json\/wp\/v2\/media?parent=5732"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/pharmaceuticalcarrier.com\/index.php\/wp-json\/wp\/v2\/categories?post=5732"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/pharmaceuticalcarrier.com\/index.php\/wp-json\/wp\/v2\/tags?post=5732"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}