{"id":5829,"date":"2023-10-11T08:54:13","date_gmt":"2023-10-11T03:24:13","guid":{"rendered":"https:\/\/pharmaceuticalcarrier.com\/?p=5829"},"modified":"2023-10-11T20:22:44","modified_gmt":"2023-10-11T14:52:44","slug":"standard-operating-procedure-sop-cleaning-and-operation-of-bod-incubator-30c-35c","status":"publish","type":"post","link":"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/11\/standard-operating-procedure-sop-cleaning-and-operation-of-bod-incubator-30c-35c\/","title":{"rendered":"Standard Operating Procedure (SOP) Cleaning and Operation of BOD Incubator (30\u00b0C &#8211; 35\u00b0C)"},"content":{"rendered":"\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_76 counter-hierarchy ez-toc-counter ez-toc-transparent ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewBox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewBox=\"0 0 24 24\" version=\"1.2\" baseProfile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/11\/standard-operating-procedure-sop-cleaning-and-operation-of-bod-incubator-30c-35c\/#1_Purpose_of_Cleaning_and_Operation_of_BOD_Incubator_30%C2%B0C_%E2%80%93_35%C2%B0C\" >1.. Purpose of Cleaning and Operation of BOD Incubator (30\u00b0C &#8211; 35\u00b0C)<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/11\/standard-operating-procedure-sop-cleaning-and-operation-of-bod-incubator-30c-35c\/#2_Scope_of_Cleaning_and_Operation_of_BOD_Incubator_30%C2%B0C_%E2%80%93_35%C2%B0C\" >2. Scope of Cleaning and Operation of BOD Incubator (30\u00b0C &#8211; 35\u00b0C)<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/11\/standard-operating-procedure-sop-cleaning-and-operation-of-bod-incubator-30c-35c\/#3_Equipment_and_Materials_involved_in_Cleaning_and_Operation_of_BOD_Incubator_30%C2%B0C_%E2%80%93_35%C2%B0C\" >3.. Equipment and Materials involved in Cleaning and Operation of BOD Incubator (30\u00b0C &#8211; 35\u00b0C)<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/11\/standard-operating-procedure-sop-cleaning-and-operation-of-bod-incubator-30c-35c\/#4_Cleaning_Procedure\" >4. Cleaning Procedure<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/11\/standard-operating-procedure-sop-cleaning-and-operation-of-bod-incubator-30c-35c\/#41_Daily_Cleaning\" >4.1 Daily Cleaning<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/11\/standard-operating-procedure-sop-cleaning-and-operation-of-bod-incubator-30c-35c\/#42_Weekly_Cleaning\" >4.2. Weekly Cleaning<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/11\/standard-operating-procedure-sop-cleaning-and-operation-of-bod-incubator-30c-35c\/#5_Operation_Procedure\" >5. Operation Procedure<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/11\/standard-operating-procedure-sop-cleaning-and-operation-of-bod-incubator-30c-35c\/#51_Start-Up_Procedure\" >5.1. Start-Up Procedure<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/11\/standard-operating-procedure-sop-cleaning-and-operation-of-bod-incubator-30c-35c\/#52_Sample_Placement\" >5.2. Sample Placement<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/11\/standard-operating-procedure-sop-cleaning-and-operation-of-bod-incubator-30c-35c\/#53_Monitoring\" >5.3. Monitoring<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/11\/standard-operating-procedure-sop-cleaning-and-operation-of-bod-incubator-30c-35c\/#54_Shutdown_Procedure\" >5.4. Shutdown Procedure<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/11\/standard-operating-procedure-sop-cleaning-and-operation-of-bod-incubator-30c-35c\/#6_Documentation\" >6. Documentation<\/a><\/li><\/ul><\/nav><\/div>\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"1_Purpose_of_Cleaning_and_Operation_of_BOD_Incubator_30%C2%B0C_%E2%80%93_35%C2%B0C\"><\/span><strong>1.. Purpose of Cleaning and Operation of BOD Incubator (30\u00b0C &#8211; 35\u00b0C)<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>This SOP outlines the procedures for the proper cleaning and operation of a BOD Incubator to ensure accurate and reliable performance.<\/p><div class=\"pharm-content\" id=\"pharm-3824843732\"><script async src=\"\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-8402705006112223\" crossorigin=\"anonymous\"><\/script><ins class=\"adsbygoogle\" style=\"display:block;\" data-ad-client=\"ca-pub-8402705006112223\" \ndata-ad-slot=\"7652789694\" \ndata-ad-format=\"auto\"><\/ins>\n<script> \n(adsbygoogle = window.adsbygoogle || []).push({}); \n<\/script>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"2_Scope_of_Cleaning_and_Operation_of_BOD_Incubator_30%C2%B0C_%E2%80%93_35%C2%B0C\"><\/span><strong>2. Scope of Cleaning and Operation of BOD Incubator (30\u00b0C &#8211; 35\u00b0C)<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>This procedure applies to all personnel responsible for using and maintaining the BOD Incubator.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"3_Equipment_and_Materials_involved_in_Cleaning_and_Operation_of_BOD_Incubator_30%C2%B0C_%E2%80%93_35%C2%B0C\"><\/span><strong>3.. Equipment and Materials involved in Cleaning and Operation of BOD Incubator (30\u00b0C &#8211; 35\u00b0C)<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>BOD Incubator<\/li>\n\n\n\n<li>Disinfectant solution<\/li>\n\n\n\n<li>Soft cloth<\/li>\n\n\n\n<li>Thermometer<\/li>\n\n\n\n<li>BOD bottles<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"4_Cleaning_Procedure\"><\/span><strong>4. Cleaning Procedure<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"41_Daily_Cleaning\"><\/span><strong>4.1 Daily Cleaning<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Power off the BOD Incubator and unplug it from the electrical source.<\/li>\n\n\n\n<li>Remove all samples and items from the incubator.<\/li>\n\n\n\n<li>Wipe down the interior surfaces, including shelves, with a soft cloth dampened with a disinfectant solution.<\/li>\n\n\n\n<li>Ensure that no residue or spillage remains inside the incubator.<\/li>\n\n\n\n<li>Clean the exterior surfaces of the incubator, including the control panel, using a separate cloth.<\/li>\n\n\n\n<li>Allow the incubator to air dry before reusing.<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"42_Weekly_Cleaning\"><\/span><strong>4.2. Weekly Cleaning<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Follow the daily cleaning procedure.<\/li>\n\n\n\n<li>Check the air filters and replace them if they are clogged or dirty.<\/li>\n\n\n\n<li>Inspect the door gasket for wear or damage; replace if necessary.<\/li>\n\n\n\n<li>Verify the accuracy of the temperature display with a calibrated thermometer.<\/li>\n\n\n\n<li>Record all maintenance and cleaning activities in a logbook.<\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"5_Operation_Procedure\"><\/span><strong>5. Operation Procedure<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"51_Start-Up_Procedure\"><\/span><strong>5.1. Start-Up Procedure<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Ensure that the BOD Incubator is on a level surface and adequately ventilated.<\/li>\n\n\n\n<li>Plug in the incubator and power it on.<\/li>\n\n\n\n<li>Set the temperature to the desired range (30\u00b0C &#8211; 35\u00b0C).<\/li>\n\n\n\n<li>Allow the incubator to stabilize for at least 30 minutes before placing samples inside.<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"52_Sample_Placement\"><\/span><strong>5.2. Sample Placement<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Place BOD bottles or samples evenly on the shelves within the incubator.<\/li>\n\n\n\n<li>Avoid overcrowding to ensure proper air circulation.<\/li>\n\n\n\n<li>Record the sample placement in a logbook, including bottle locations.<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"53_Monitoring\"><\/span><strong>5.3. Monitoring<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Regularly monitor and record the temperature inside the incubator using a calibrated thermometer.<\/li>\n\n\n\n<li>Check the status of samples, ensuring they are properly sealed and labeled.<\/li>\n\n\n\n<li>Address any deviations or alarms promptly, following manufacturer guidelines.<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"54_Shutdown_Procedure\"><\/span><strong>5.4. Shutdown Procedure<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Power off the incubator.<\/li>\n\n\n\n<li>Remove all samples and items from the incubator.<\/li>\n\n\n\n<li>Clean the interior and exterior following the cleaning procedure outlined in Section IV.<\/li>\n\n\n\n<li>Ensure the incubator is dry and free of residues before closing the door.<\/li>\n\n\n\n<li>Leave the door slightly ajar to prevent odors and moisture buildup.<\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"6_Documentation\"><\/span><strong>6. Documentation<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Maintain a logbook to record all cleaning, maintenance, and operation activities.<\/li>\n\n\n\n<li>Include dates, names of personnel involved, and any deviations from the standard procedures.                           For more articles,\u00a0<strong><a href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/ayurveda\/\">Kindly Click<\/a>\u00a0here<\/strong>.                                                                                                     For pharmaceutical jobs, follow us on<strong>\u00a0<a href=\"https:\/\/www.linkedin.com\/company\/pharmaceuticalcarrier\/?viewAsMember=true\" target=\"_blank\" rel=\"noreferrer noopener\">LinkedIn<\/a><\/strong>                                                                                  <strong>For Editable SOPs in word format contact us on\u00a0<a href=\"mailto:info@pharmaceuticalcarrier.com\">info@pharmaceuticalcarrier.com<\/a><\/strong>\u00a0                         For more information kindly follow us on pharmaguidelines.co.uk\u00a0         <\/li>\n<\/ol>\n","protected":false},"excerpt":{"rendered":"<p>&#8220;Learn how to properly clean and operate a BOD Incubator (30\u00b0C &#8211; 35\u00b0C) with this comprehensive Standard Operating Procedure (SOP). Ensure accurate experiments and equipment longevity in your laboratory.&#8221;<\/p>\n","protected":false},"author":1,"featured_media":5599,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","footnotes":""},"categories":[165],"tags":[852,773,851,654,371,853,166,167,528],"class_list":["post-5829","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-standard-operating-procedure","tag-bod-incubator","tag-cleaning","tag-data-recording","tag-laboratory-equipment","tag-maintenance","tag-operation","tag-sop","tag-standard-operating-procedure","tag-temperature-control"],"uagb_featured_image_src":{"full":["https:\/\/pharmaceuticalcarrier.com\/wp-content\/uploads\/2023\/09\/Standard-operating-procedure.jpg",1200,720,false],"thumbnail":["https:\/\/pharmaceuticalcarrier.com\/wp-content\/uploads\/2023\/09\/Standard-operating-procedure-150x150.jpg",150,150,true],"medium":["https:\/\/pharmaceuticalcarrier.com\/wp-content\/uploads\/2023\/09\/Standard-operating-procedure-300x180.jpg",300,180,true],"medium_large":["https:\/\/pharmaceuticalcarrier.com\/wp-content\/uploads\/2023\/09\/Standard-operating-procedure-768x461.jpg",640,384,true],"large":["https:\/\/pharmaceuticalcarrier.com\/wp-content\/uploads\/2023\/09\/Standard-operating-procedure-1024x614.jpg",640,384,true],"1536x1536":["https:\/\/pharmaceuticalcarrier.com\/wp-content\/uploads\/2023\/09\/Standard-operating-procedure.jpg",1200,720,false],"2048x2048":["https:\/\/pharmaceuticalcarrier.com\/wp-content\/uploads\/2023\/09\/Standard-operating-procedure.jpg",1200,720,false],"authorship-box-avatar":["https:\/\/pharmaceuticalcarrier.com\/wp-content\/uploads\/2023\/09\/Standard-operating-procedure-150x150.jpg",150,150,true],"authorship-box-related":["https:\/\/pharmaceuticalcarrier.com\/wp-content\/uploads\/2023\/09\/Standard-operating-procedure-70x70.jpg",70,70,true],"sow-carousel-default":["https:\/\/pharmaceuticalcarrier.com\/wp-content\/uploads\/2023\/09\/Standard-operating-procedure.jpg",272,163,false]},"uagb_author_info":{"display_name":"Pharmacareer","author_link":"https:\/\/pharmaceuticalcarrier.com\/index.php\/author\/grandirpharmagmail-com\/"},"uagb_comment_info":0,"uagb_excerpt":"\"Learn how to properly clean and operate a BOD Incubator (30\u00b0C - 35\u00b0C) with this comprehensive Standard Operating Procedure (SOP). Ensure accurate experiments and equipment longevity in your laboratory.\"","amp_enabled":true,"_links":{"self":[{"href":"https:\/\/pharmaceuticalcarrier.com\/index.php\/wp-json\/wp\/v2\/posts\/5829","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pharmaceuticalcarrier.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/pharmaceuticalcarrier.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/pharmaceuticalcarrier.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/pharmaceuticalcarrier.com\/index.php\/wp-json\/wp\/v2\/comments?post=5829"}],"version-history":[{"count":3,"href":"https:\/\/pharmaceuticalcarrier.com\/index.php\/wp-json\/wp\/v2\/posts\/5829\/revisions"}],"predecessor-version":[{"id":5862,"href":"https:\/\/pharmaceuticalcarrier.com\/index.php\/wp-json\/wp\/v2\/posts\/5829\/revisions\/5862"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pharmaceuticalcarrier.com\/index.php\/wp-json\/wp\/v2\/media\/5599"}],"wp:attachment":[{"href":"https:\/\/pharmaceuticalcarrier.com\/index.php\/wp-json\/wp\/v2\/media?parent=5829"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/pharmaceuticalcarrier.com\/index.php\/wp-json\/wp\/v2\/categories?post=5829"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/pharmaceuticalcarrier.com\/index.php\/wp-json\/wp\/v2\/tags?post=5829"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}