{"id":5889,"date":"2023-10-14T21:20:30","date_gmt":"2023-10-14T15:50:30","guid":{"rendered":"https:\/\/pharmaceuticalcarrier.com\/?p=5889"},"modified":"2023-10-15T08:13:12","modified_gmt":"2023-10-15T02:43:12","slug":"standard-operating-procedure-sop-for-proper-sample-preparation-dilution-extraction-and-filtration","status":"publish","type":"post","link":"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/14\/standard-operating-procedure-sop-for-proper-sample-preparation-dilution-extraction-and-filtration\/","title":{"rendered":"Standard Operating Procedure (SOP) for Proper Sample Preparation: Dilution, Extraction, and Filtration"},"content":{"rendered":"\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_76 counter-hierarchy ez-toc-counter ez-toc-transparent ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewBox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewBox=\"0 0 24 24\" version=\"1.2\" baseProfile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/14\/standard-operating-procedure-sop-for-proper-sample-preparation-dilution-extraction-and-filtration\/#1_Purpose_of_Proper_Sample_Preparation_Dilution_Extraction_and_Filtration\" >1. Purpose of Proper Sample Preparation: Dilution, Extraction, and Filtration<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/14\/standard-operating-procedure-sop-for-proper-sample-preparation-dilution-extraction-and-filtration\/#2_Scope_of_Proper_Sample_Preparation_Dilution_Extraction_and_Filtration\" >2. Scope of Proper Sample Preparation: Dilution, Extraction, and Filtration<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/14\/standard-operating-procedure-sop-for-proper-sample-preparation-dilution-extraction-and-filtration\/#3_Definitions_involved_in_Proper_Sample_Preparation_Dilution_Extraction_and_Filtration\" >3. Definitions involved in Proper Sample Preparation: Dilution, Extraction, and Filtration<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/14\/standard-operating-procedure-sop-for-proper-sample-preparation-dilution-extraction-and-filtration\/#31_Sample\" >3.1 Sample:<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/14\/standard-operating-procedure-sop-for-proper-sample-preparation-dilution-extraction-and-filtration\/#32_Dilution\" >3.2 Dilution:<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/14\/standard-operating-procedure-sop-for-proper-sample-preparation-dilution-extraction-and-filtration\/#33_Extraction\" >3.3 Extraction:<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/14\/standard-operating-procedure-sop-for-proper-sample-preparation-dilution-extraction-and-filtration\/#34_Filtration\" >3.4 Filtration:<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/14\/standard-operating-procedure-sop-for-proper-sample-preparation-dilution-extraction-and-filtration\/#4_Responsibilities_involved_in_Proper_Sample_Preparation_Dilution_Extraction_and_Filtration\" >4. Responsibilities involved in Proper Sample Preparation: Dilution, Extraction, and Filtration<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/14\/standard-operating-procedure-sop-for-proper-sample-preparation-dilution-extraction-and-filtration\/#41_Laboratory_Manager\" >4.1. Laboratory Manager<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/14\/standard-operating-procedure-sop-for-proper-sample-preparation-dilution-extraction-and-filtration\/#42_Sample_Preparation_Technician\" >4.2. Sample Preparation Technician<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/14\/standard-operating-procedure-sop-for-proper-sample-preparation-dilution-extraction-and-filtration\/#5_Sample_Dilution\" >5. Sample Dilution<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/14\/standard-operating-procedure-sop-for-proper-sample-preparation-dilution-extraction-and-filtration\/#51_Pre-Dilution_Preparations\" >5.1. Pre-Dilution Preparations<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-13\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/14\/standard-operating-procedure-sop-for-proper-sample-preparation-dilution-extraction-and-filtration\/#52_Dilution_Procedure\" >5.2. Dilution Procedure<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-14\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/14\/standard-operating-procedure-sop-for-proper-sample-preparation-dilution-extraction-and-filtration\/#6_Sample_Extraction\" >6. Sample Extraction<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-15\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/14\/standard-operating-procedure-sop-for-proper-sample-preparation-dilution-extraction-and-filtration\/#61_Pre-Extraction_Preparations\" >6.1. Pre-Extraction Preparations<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-16\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/14\/standard-operating-procedure-sop-for-proper-sample-preparation-dilution-extraction-and-filtration\/#62_Extraction_Procedure\" >6.2. Extraction Procedure<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-17\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/14\/standard-operating-procedure-sop-for-proper-sample-preparation-dilution-extraction-and-filtration\/#7_Sample_Filtration\" >7. Sample Filtration<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-18\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/14\/standard-operating-procedure-sop-for-proper-sample-preparation-dilution-extraction-and-filtration\/#71_Pre-Filtration_Preparations\" >7.1. Pre-Filtration Preparations<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-19\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/14\/standard-operating-procedure-sop-for-proper-sample-preparation-dilution-extraction-and-filtration\/#72_Filtration_Procedure\" >7.2. Filtration Procedure<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-20\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/14\/standard-operating-procedure-sop-for-proper-sample-preparation-dilution-extraction-and-filtration\/#8_Record_Keeping\" >8. Record Keeping<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-21\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/14\/standard-operating-procedure-sop-for-proper-sample-preparation-dilution-extraction-and-filtration\/#81_Sample_Preparation_Records\" >8.1. Sample Preparation Records<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-22\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/14\/standard-operating-procedure-sop-for-proper-sample-preparation-dilution-extraction-and-filtration\/#82_Schedule\" >8.2. Schedule<\/a><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"1_Purpose_of_Proper_Sample_Preparation_Dilution_Extraction_and_Filtration\"><\/span><strong>1. Purpose of Proper Sample Preparation: Dilution, Extraction, and Filtration<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>The purpose of this Standard Operating Procedure (SOP) for Proper Sample Preparation: Dilution, Extraction, and Filtration is to establish a systematic process for proper sample preparation, including dilution, extraction, and filtration, at [Company Name]. This procedure ensures that samples are accurately and consistently prepared for analytical testing.<\/p><div class=\"pharm-content\" id=\"pharm-276105068\"><script async src=\"\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-8402705006112223\" crossorigin=\"anonymous\"><\/script><ins class=\"adsbygoogle\" style=\"display:block;\" data-ad-client=\"ca-pub-8402705006112223\" \ndata-ad-slot=\"7652789694\" \ndata-ad-format=\"auto\"><\/ins>\n<script> \n(adsbygoogle = window.adsbygoogle || []).push({}); \n<\/script>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"2_Scope_of_Proper_Sample_Preparation_Dilution_Extraction_and_Filtration\"><\/span><strong>2. Scope of Proper Sample Preparation: Dilution, Extraction, and Filtration<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>This SOP for Proper Sample Preparation: Dilution, Extraction, and Filtration applies to all personnel responsible for sample preparation within [Company Name]. It covers the processes of dilution, extraction, and filtration, which may be used in various laboratory applications.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"3_Definitions_involved_in_Proper_Sample_Preparation_Dilution_Extraction_and_Filtration\"><\/span><strong>3. Definitions involved in Proper Sample Preparation: Dilution, Extraction, and Filtration<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"31_Sample\"><\/span>3.1 <strong>Sample<\/strong>: <span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>A representative portion of a material to be analyzed.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"32_Dilution\"><\/span>3.2 <strong>Dilution<\/strong>: <span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>The process of reducing the concentration of a sample by adding a suitable solvent.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"33_Extraction\"><\/span>3.3 <strong>Extraction<\/strong>: <span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>The process of removing specific components from a sample.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"34_Filtration\"><\/span>3.4 <strong>Filtration<\/strong>: <span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>The separation of solids from liquids by passing the sample through a filter medium.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"4_Responsibilities_involved_in_Proper_Sample_Preparation_Dilution_Extraction_and_Filtration\"><\/span><strong>4. Responsibilities involved in Proper Sample Preparation: Dilution, Extraction, and Filtration<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"41_Laboratory_Manager\"><\/span><strong>4.1. Laboratory Manager<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>4.1.1 Ensure that all sample preparation procedures are performed in compliance with this SOP.<\/p>\n\n\n\n<p>4.1.2 Allocate resources and personnel for sample preparation activities.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"42_Sample_Preparation_Technician\"><\/span><strong>4.2. Sample Preparation Technician<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>4.2.1 Perform sample preparation activities, including dilution, extraction, and filtration, as required.<\/p>\n\n\n\n<p>4.2.2 Ensure that all procedures are followed accurately and consistently.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"5_Sample_Dilution\"><\/span><strong>5. Sample Dilution<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"51_Pre-Dilution_Preparations\"><\/span><strong>5.1. Pre-Dilution Preparations<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>5.1.1 Identify the sample to be diluted and determine the required dilution factor.<\/p>\n\n\n\n<p>5.1.2 Select an appropriate diluent that is compatible with the sample and the intended analysis.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"52_Dilution_Procedure\"><\/span><strong>5.2. Dilution Procedure<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>5.2.1 Add the calculated volume of sample to an appropriate container.<\/p>\n\n\n\n<p>5.2.2 Add the calculated volume of diluent to the same container.<\/p>\n\n\n\n<p>5.2.3 Mix the contents thoroughly to achieve homogeneity.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"6_Sample_Extraction\"><\/span><strong>6. Sample Extraction<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"61_Pre-Extraction_Preparations\"><\/span><strong>6.1. Pre-Extraction Preparations<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>6.1.1 Determine the components to be extracted and select the appropriate extraction solvent.<\/p>\n\n\n\n<p>6.1.2 Prepare extraction equipment and containers.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"62_Extraction_Procedure\"><\/span><strong>6.2. Extraction Procedure<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>6.2.1 Add the sample to an extraction container.<\/p>\n\n\n\n<p>6.2.2 Add the extraction solvent to the container.<\/p>\n\n\n\n<p>6.2.3 Agitate or mix the sample and solvent as necessary.<\/p>\n\n\n\n<p>6.2.4 Allow the extraction to proceed for the specified duration.<\/p>\n\n\n\n<p>6.2.5 Separate the extracted liquid from any solid or particulate matter.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"7_Sample_Filtration\"><\/span><strong>7. Sample Filtration<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"71_Pre-Filtration_Preparations\"><\/span><strong>7.1. Pre-Filtration Preparations<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>7.1.1 Select the appropriate filter medium (e.g., paper, membrane) and filtration equipment.<\/p>\n\n\n\n<p>7.1.2 Ensure that filtration equipment is clean and properly assembled.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"72_Filtration_Procedure\"><\/span><strong>7.2. Filtration Procedure<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>7.2.1 Place the filter medium in the filtration apparatus.<\/p>\n\n\n\n<p>7.2.2 Add the extracted sample to the filter apparatus.<\/p>\n\n\n\n<p>7.2.3 Apply vacuum or pressure as needed to facilitate filtration.<\/p>\n\n\n\n<p>7.2.4 Collect the filtrate in a clean container.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"8_Record_Keeping\"><\/span><strong>8. Record Keeping<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"81_Sample_Preparation_Records\"><\/span><strong>8.1. Sample Preparation Records<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>8.1.1 Maintain detailed records for each sample preparation step, including dilution, extraction, and filtration.<\/p>\n\n\n\n<p>8.1.2 Include information about sample identification, dates, and personnel involved.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"82_Schedule\"><\/span><strong>8.2. Schedule<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>8.2.1 Establish a schedule for sample preparation activities as needed.<\/p>\n\n\n\n<p>8.2.2 Ensure that the schedule is consistently followed.<\/p>\n\n\n\n<p>For more articles,&nbsp;<strong><a href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/ayurveda\/\">Kindly Click<\/a>&nbsp;here<\/strong>.<\/p>\n\n\n\n<p>For pharmaceutical jobs, follow us on<strong>&nbsp;<a href=\"https:\/\/www.linkedin.com\/company\/pharmaceuticalcarrier\/?viewAsMember=true\" target=\"_blank\" rel=\"noreferrer noopener\">LinkedIn<\/a><\/strong>&nbsp;<\/p>\n\n\n\n<p><strong>For Editable SOPs in word format contact us on&nbsp;<a href=\"mailto:info@pharmaceuticalcarrier.com\">info@pharmaceuticalcarrier.com<\/a><\/strong>&nbsp;<\/p>\n\n\n\n<p>For more information kindly follow us on pharmaguidelines.co.uk<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Discover a comprehensive Standard Operating Procedure (SOP) for proper sample preparation, including dilution, extraction, and filtration, designed to ensure accuracy and consistency in laboratory testing. This SOP covers the responsibilities, procedures, record-keeping, and equipment requirements, offering a structured framework for maintaining high-quality sample preparation in your organization while meeting regulatory standards.<\/p>\n","protected":false},"author":1,"featured_media":5599,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","footnotes":""},"categories":[165],"tags":[864,465,869,866,867,833,677,865,257,829,348,868,625,166],"class_list":["post-5889","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-standard-operating-procedure","tag-analytical-testing","tag-calibration","tag-dilution","tag-extraction","tag-filtration","tag-laboratory-management","tag-laboratory-procedures","tag-laboratory-technician","tag-quality-control","tag-record-keeping-2","tag-regulatory-compliance","tag-revision-history","tag-sample-preparation","tag-sop"],"uagb_featured_image_src":{"full":["https:\/\/pharmaceuticalcarrier.com\/wp-content\/uploads\/2023\/09\/Standard-operating-procedure.jpg",1200,720,false],"thumbnail":["https:\/\/pharmaceuticalcarrier.com\/wp-content\/uploads\/2023\/09\/Standard-operating-procedure-150x150.jpg",150,150,true],"medium":["https:\/\/pharmaceuticalcarrier.com\/wp-content\/uploads\/2023\/09\/Standard-operating-procedure-300x180.jpg",300,180,true],"medium_large":["https:\/\/pharmaceuticalcarrier.com\/wp-content\/uploads\/2023\/09\/Standard-operating-procedure-768x461.jpg",640,384,true],"large":["https:\/\/pharmaceuticalcarrier.com\/wp-content\/uploads\/2023\/09\/Standard-operating-procedure-1024x614.jpg",640,384,true],"1536x1536":["https:\/\/pharmaceuticalcarrier.com\/wp-content\/uploads\/2023\/09\/Standard-operating-procedure.jpg",1200,720,false],"2048x2048":["https:\/\/pharmaceuticalcarrier.com\/wp-content\/uploads\/2023\/09\/Standard-operating-procedure.jpg",1200,720,false],"authorship-box-avatar":["https:\/\/pharmaceuticalcarrier.com\/wp-content\/uploads\/2023\/09\/Standard-operating-procedure-150x150.jpg",150,150,true],"authorship-box-related":["https:\/\/pharmaceuticalcarrier.com\/wp-content\/uploads\/2023\/09\/Standard-operating-procedure-70x70.jpg",70,70,true],"sow-carousel-default":["https:\/\/pharmaceuticalcarrier.com\/wp-content\/uploads\/2023\/09\/Standard-operating-procedure.jpg",272,163,false]},"uagb_author_info":{"display_name":"Pharmacareer","author_link":"https:\/\/pharmaceuticalcarrier.com\/index.php\/author\/grandirpharmagmail-com\/"},"uagb_comment_info":0,"uagb_excerpt":"Discover a comprehensive Standard Operating Procedure (SOP) for proper sample preparation, including dilution, extraction, and filtration, designed to ensure accuracy and consistency in laboratory testing. This SOP covers the responsibilities, procedures, record-keeping, and equipment requirements, offering a structured framework for maintaining high-quality sample preparation in your organization while meeting regulatory standards.","amp_enabled":true,"_links":{"self":[{"href":"https:\/\/pharmaceuticalcarrier.com\/index.php\/wp-json\/wp\/v2\/posts\/5889","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pharmaceuticalcarrier.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/pharmaceuticalcarrier.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/pharmaceuticalcarrier.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/pharmaceuticalcarrier.com\/index.php\/wp-json\/wp\/v2\/comments?post=5889"}],"version-history":[{"count":1,"href":"https:\/\/pharmaceuticalcarrier.com\/index.php\/wp-json\/wp\/v2\/posts\/5889\/revisions"}],"predecessor-version":[{"id":5890,"href":"https:\/\/pharmaceuticalcarrier.com\/index.php\/wp-json\/wp\/v2\/posts\/5889\/revisions\/5890"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pharmaceuticalcarrier.com\/index.php\/wp-json\/wp\/v2\/media\/5599"}],"wp:attachment":[{"href":"https:\/\/pharmaceuticalcarrier.com\/index.php\/wp-json\/wp\/v2\/media?parent=5889"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/pharmaceuticalcarrier.com\/index.php\/wp-json\/wp\/v2\/categories?post=5889"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/pharmaceuticalcarrier.com\/index.php\/wp-json\/wp\/v2\/tags?post=5889"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}