{"id":5893,"date":"2023-10-17T08:41:39","date_gmt":"2023-10-17T03:11:39","guid":{"rendered":"https:\/\/pharmaceuticalcarrier.com\/?p=5893"},"modified":"2023-10-17T08:41:52","modified_gmt":"2023-10-17T03:11:52","slug":"standard-operating-procedure-sop-for-preparing-storing-and-handling-mobile-phases-with-degassing-techniques","status":"publish","type":"post","link":"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/17\/standard-operating-procedure-sop-for-preparing-storing-and-handling-mobile-phases-with-degassing-techniques\/","title":{"rendered":"Standard Operating Procedure (SOP) for Preparing, Storing, and Handling Mobile Phases with Degassing Techniques"},"content":{"rendered":"\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_76 counter-hierarchy ez-toc-counter ez-toc-transparent ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewBox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewBox=\"0 0 24 24\" version=\"1.2\" baseProfile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/17\/standard-operating-procedure-sop-for-preparing-storing-and-handling-mobile-phases-with-degassing-techniques\/#1_Purpose_of_Preparing_Storing_and_Handling_Mobile_Phases_with_Degassing_Techniques\" >1. Purpose of Preparing, Storing, and Handling Mobile Phases with Degassing Techniques<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/17\/standard-operating-procedure-sop-for-preparing-storing-and-handling-mobile-phases-with-degassing-techniques\/#2_Scope_of_Preparing_Storing_and_Handling_Mobile_Phases_with_Degassing_Techniques\" >2. Scope of Preparing, Storing, and Handling Mobile Phases with Degassing Techniques<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/17\/standard-operating-procedure-sop-for-preparing-storing-and-handling-mobile-phases-with-degassing-techniques\/#3_Definitions\" >3. Definitions<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/17\/standard-operating-procedure-sop-for-preparing-storing-and-handling-mobile-phases-with-degassing-techniques\/#31_Mobile_Phase\" >3.1 Mobile Phase:<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/17\/standard-operating-procedure-sop-for-preparing-storing-and-handling-mobile-phases-with-degassing-techniques\/#32_Degassing\" >3.2 Degassing:<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/17\/standard-operating-procedure-sop-for-preparing-storing-and-handling-mobile-phases-with-degassing-techniques\/#4_Responsibilities\" >4. Responsibilities<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/17\/standard-operating-procedure-sop-for-preparing-storing-and-handling-mobile-phases-with-degassing-techniques\/#41_Laboratory_Manager\" >4.1. Laboratory Manager<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/17\/standard-operating-procedure-sop-for-preparing-storing-and-handling-mobile-phases-with-degassing-techniques\/#42_Analysts\" >4.2. Analysts<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/17\/standard-operating-procedure-sop-for-preparing-storing-and-handling-mobile-phases-with-degassing-techniques\/#5_Mobile_Phase_Selection\" >5. Mobile Phase Selection<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/17\/standard-operating-procedure-sop-for-preparing-storing-and-handling-mobile-phases-with-degassing-techniques\/#51_Solvent_Compatibility\" >5.1. Solvent Compatibility<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/17\/standard-operating-procedure-sop-for-preparing-storing-and-handling-mobile-phases-with-degassing-techniques\/#52_Mobile_Phase_Composition\" >5.2. Mobile Phase Composition<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/17\/standard-operating-procedure-sop-for-preparing-storing-and-handling-mobile-phases-with-degassing-techniques\/#6_Mobile_Phase_Preparation\" >6. Mobile Phase Preparation<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-13\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/17\/standard-operating-procedure-sop-for-preparing-storing-and-handling-mobile-phases-with-degassing-techniques\/#61_Solvent_Quality\" >6.1. Solvent Quality<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-14\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/17\/standard-operating-procedure-sop-for-preparing-storing-and-handling-mobile-phases-with-degassing-techniques\/#62_Mixing_and_Deaeration\" >6.2. Mixing and Deaeration<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-15\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/17\/standard-operating-procedure-sop-for-preparing-storing-and-handling-mobile-phases-with-degassing-techniques\/#7_Mobile_Phase_Storage\" >7. Mobile Phase Storage<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-16\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/17\/standard-operating-procedure-sop-for-preparing-storing-and-handling-mobile-phases-with-degassing-techniques\/#71_Storage_Conditions\" >7.1. Storage Conditions<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-17\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/17\/standard-operating-procedure-sop-for-preparing-storing-and-handling-mobile-phases-with-degassing-techniques\/#72_Labeling\" >7.2. Labeling<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-18\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/17\/standard-operating-procedure-sop-for-preparing-storing-and-handling-mobile-phases-with-degassing-techniques\/#8_Handling_Mobile_Phases\" >8. Handling Mobile Phases<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-19\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/17\/standard-operating-procedure-sop-for-preparing-storing-and-handling-mobile-phases-with-degassing-techniques\/#81_System_Priming\" >8.1. System Priming<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-20\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/17\/standard-operating-procedure-sop-for-preparing-storing-and-handling-mobile-phases-with-degassing-techniques\/#9_Record_Keeping\" >9. Record Keeping<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-21\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/17\/standard-operating-procedure-sop-for-preparing-storing-and-handling-mobile-phases-with-degassing-techniques\/#91_Records\" >9.1 Records<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-22\" href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/2023\/10\/17\/standard-operating-procedure-sop-for-preparing-storing-and-handling-mobile-phases-with-degassing-techniques\/#92_Schedule\" >9.2. Schedule<\/a><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"1_Purpose_of_Preparing_Storing_and_Handling_Mobile_Phases_with_Degassing_Techniques\"><\/span><strong>1. Purpose of Preparing, Storing, and Handling Mobile Phases with Degassing Techniques<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>The purpose of this Standard Operating Procedure (SOP) is to provide guidelines for the proper preparation, storage, and handling of mobile phases, including the degassing process, to ensure the accuracy and consistency of analyses using liquid chromatography systems at [Company Name].<\/p><div class=\"pharm-content\" id=\"pharm-2076260941\"><script async src=\"\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-8402705006112223\" crossorigin=\"anonymous\"><\/script><ins class=\"adsbygoogle\" style=\"display:block;\" data-ad-client=\"ca-pub-8402705006112223\" \ndata-ad-slot=\"7652789694\" \ndata-ad-format=\"auto\"><\/ins>\n<script> \n(adsbygoogle = window.adsbygoogle || []).push({}); \n<\/script>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"2_Scope_of_Preparing_Storing_and_Handling_Mobile_Phases_with_Degassing_Techniques\"><\/span><strong>2. Scope of Preparing, Storing, and Handling Mobile Phases with Degassing Techniques<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>This SOP applies to all personnel responsible for preparing, storing, and handling mobile phases within the [Company Name] laboratory. It covers the entire process, from selection and preparation of solvents to degassing and storage.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"3_Definitions\"><\/span><strong>3. Definitions<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"31_Mobile_Phase\"><\/span>3.1 <strong>Mobile Phase<\/strong>: <span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>A solvent or mixture of solvents used in liquid chromatography for sample separation.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"32_Degassing\"><\/span>3.2 <strong>Degassing<\/strong>: <span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>The removal of dissolved gases from mobile phases to prevent air bubble formation and ensure system stability.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"4_Responsibilities\"><\/span><strong>4. Responsibilities<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"41_Laboratory_Manager\"><\/span><strong>4.1. Laboratory Manager<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>4.1.1 Ensure that all mobile phase preparations adhere to this SOP.<\/p>\n\n\n\n<p>4.1.2 Allocate resources and oversee the laboratory&#8217;s compliance.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"42_Analysts\"><\/span><strong>4.2. Analysts<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>4.2.1 Follow this SOP for mobile phase preparation and handling.<\/p>\n\n\n\n<p>4.2.2 Report any deviations or issues to the Laboratory Manager.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"5_Mobile_Phase_Selection\"><\/span><strong>5. Mobile Phase Selection<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"51_Solvent_Compatibility\"><\/span><strong>5.1. Solvent Compatibility<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>5.1.1 Select solvents that are compatible with the sample and the chromatographic column.<\/p>\n\n\n\n<p>5.1.2 Consider the volatility, UV cutoff, and elution strength of solvents.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"52_Mobile_Phase_Composition\"><\/span><strong>5.2. Mobile Phase Composition<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>5.2.1 Prepare the mobile phase according to the specified chromatographic method.<\/p>\n\n\n\n<p>5.2.2 Ensure accurate solvent ratios for reproducible results.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"6_Mobile_Phase_Preparation\"><\/span><strong>6. Mobile Phase Preparation<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"61_Solvent_Quality\"><\/span><strong>6.1. Solvent Quality<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>6.1.1 Use high-purity solvents suitable for liquid chromatography.<\/p>\n\n\n\n<p>6.1.2 Filter solvents if necessary to remove particulates.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"62_Mixing_and_Deaeration\"><\/span><strong>6.2. Mixing and Deaeration<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>6.2.1 Mix solvents thoroughly to achieve a homogenous mixture.<\/p>\n\n\n\n<p>6.2.2 Employ appropriate degassing techniques, such as sonication or sparging, to remove dissolved gases.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"7_Mobile_Phase_Storage\"><\/span><strong>7. Mobile Phase Storage<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"71_Storage_Conditions\"><\/span><strong>7.1. Storage Conditions<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>7.1.1 Store mobile phases in clean, well-sealed containers.<\/p>\n\n\n\n<p>7.1.2 Protect mobile phases from light and extreme temperatures.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"72_Labeling\"><\/span><strong>7.2. Labeling<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>7.2.1 Clearly label mobile phase containers with contents, preparation date, and expiration date.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"8_Handling_Mobile_Phases\"><\/span><strong>8. Handling Mobile Phases<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"81_System_Priming\"><\/span><strong>8.1. System Priming<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>8.1.1 Prime the liquid chromatography system with the prepared mobile phase before analysis.<\/p>\n\n\n\n<p>8.1.2 Avoid air bubble formation in the system.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"9_Record_Keeping\"><\/span><strong>9. Record Keeping<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"91_Records\"><\/span><strong>9.1 Records<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>9.1.1 Maintain detailed records of mobile phase preparation, including composition, degassing, and storage details.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"92_Schedule\"><\/span><strong>9.2. Schedule<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>9.2.1 Establish a schedule for routine mobile phase preparation and replacement.<\/p>\n\n\n\n<p>9.2.2 Ensure compliance with the schedule.<\/p>\n\n\n\n<p>For more articles,&nbsp;<strong><a href=\"https:\/\/pharmaceuticalcarrier.com\/index.php\/ayurveda\/\">Kindly Click<\/a>&nbsp;here<\/strong>.<\/p>\n\n\n\n<p>For pharmaceutical jobs, follow us on<strong>&nbsp;<a href=\"https:\/\/www.linkedin.com\/company\/pharmaceuticalcarrier\/?viewAsMember=true\" target=\"_blank\" rel=\"noreferrer noopener\">LinkedIn<\/a><\/strong>&nbsp;<\/p>\n\n\n\n<p><strong>For Editable SOPs in word format contact us on&nbsp;<a href=\"mailto:info@pharmaceuticalcarrier.com\">info@pharmaceuticalcarrier.com<\/a><\/strong>&nbsp;<\/p>\n\n\n\n<p>For more information kindly follow us on pharmaguidelines.co.uk<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Discover a comprehensive Standard Operating Procedure (SOP) for the preparation, storage, and handling of mobile phases in liquid chromatography. This detailed SOP includes degassing techniques, definitions, responsibilities, and crucial steps for ensuring accurate and reliable chromatographic analyses. It is designed to help laboratories maintain quality control, adhere to industry standards, and meet regulatory compliance requirements.<\/p>\n","protected":false},"author":1,"featured_media":5599,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","footnotes":""},"categories":[165],"tags":[876,878,871,875,873,879,257,829,868,877,166,874],"class_list":["post-5893","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-standard-operating-procedure","tag-degassing-techniques","tag-handling","tag-laboratory","tag-liquid-chromatography","tag-mobile-phase","tag-preparation","tag-quality-control","tag-record-keeping-2","tag-revision-history","tag-solvent-compatibility","tag-sop","tag-storage"],"uagb_featured_image_src":{"full":["https:\/\/pharmaceuticalcarrier.com\/wp-content\/uploads\/2023\/09\/Standard-operating-procedure.jpg",1200,720,false],"thumbnail":["https:\/\/pharmaceuticalcarrier.com\/wp-content\/uploads\/2023\/09\/Standard-operating-procedure-150x150.jpg",150,150,true],"medium":["https:\/\/pharmaceuticalcarrier.com\/wp-content\/uploads\/2023\/09\/Standard-operating-procedure-300x180.jpg",300,180,true],"medium_large":["https:\/\/pharmaceuticalcarrier.com\/wp-content\/uploads\/2023\/09\/Standard-operating-procedure-768x461.jpg",640,384,true],"large":["https:\/\/pharmaceuticalcarrier.com\/wp-content\/uploads\/2023\/09\/Standard-operating-procedure-1024x614.jpg",640,384,true],"1536x1536":["https:\/\/pharmaceuticalcarrier.com\/wp-content\/uploads\/2023\/09\/Standard-operating-procedure.jpg",1200,720,false],"2048x2048":["https:\/\/pharmaceuticalcarrier.com\/wp-content\/uploads\/2023\/09\/Standard-operating-procedure.jpg",1200,720,false],"authorship-box-avatar":["https:\/\/pharmaceuticalcarrier.com\/wp-content\/uploads\/2023\/09\/Standard-operating-procedure-150x150.jpg",150,150,true],"authorship-box-related":["https:\/\/pharmaceuticalcarrier.com\/wp-content\/uploads\/2023\/09\/Standard-operating-procedure-70x70.jpg",70,70,true],"sow-carousel-default":["https:\/\/pharmaceuticalcarrier.com\/wp-content\/uploads\/2023\/09\/Standard-operating-procedure.jpg",272,163,false]},"uagb_author_info":{"display_name":"Pharmacareer","author_link":"https:\/\/pharmaceuticalcarrier.com\/index.php\/author\/grandirpharmagmail-com\/"},"uagb_comment_info":0,"uagb_excerpt":"Discover a comprehensive Standard Operating Procedure (SOP) for the preparation, storage, and handling of mobile phases in liquid chromatography. This detailed SOP includes degassing techniques, definitions, responsibilities, and crucial steps for ensuring accurate and reliable chromatographic analyses. It is designed to help laboratories maintain quality control, adhere to industry standards, and meet regulatory compliance requirements.","amp_enabled":true,"_links":{"self":[{"href":"https:\/\/pharmaceuticalcarrier.com\/index.php\/wp-json\/wp\/v2\/posts\/5893","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pharmaceuticalcarrier.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/pharmaceuticalcarrier.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/pharmaceuticalcarrier.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/pharmaceuticalcarrier.com\/index.php\/wp-json\/wp\/v2\/comments?post=5893"}],"version-history":[{"count":1,"href":"https:\/\/pharmaceuticalcarrier.com\/index.php\/wp-json\/wp\/v2\/posts\/5893\/revisions"}],"predecessor-version":[{"id":5894,"href":"https:\/\/pharmaceuticalcarrier.com\/index.php\/wp-json\/wp\/v2\/posts\/5893\/revisions\/5894"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pharmaceuticalcarrier.com\/index.php\/wp-json\/wp\/v2\/media\/5599"}],"wp:attachment":[{"href":"https:\/\/pharmaceuticalcarrier.com\/index.php\/wp-json\/wp\/v2\/media?parent=5893"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/pharmaceuticalcarrier.com\/index.php\/wp-json\/wp\/v2\/categories?post=5893"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/pharmaceuticalcarrier.com\/index.php\/wp-json\/wp\/v2\/tags?post=5893"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}